  bel power solutions 152 north 3rd street, suite 805 san jose, ca 95112 usa ? 201 5 bel power solutions, inc. north america +1 - 866.513.2839 asia - pacific +86.755.29885888 europe, middle east +353 61 225 977 tech.support@psbel.com d - 300 0 - st02 _001 ? output power 3 0 00 w ? input voltage: o single - phase 23 0 vac o three - phase 208 vac ? power factor : o > 0. 98 @ full - load @ 230 vac single - phase o > 0. 92 @ full - load @ 208 vac three - phase ? main output s : 4 x +50 v/23. 5 a (imax total 58 a) ? auxiliary output s : +48 v/2. 5 a, +5 v/ 500 ma ? current and voltage m onitor ing ? remote inhibit the bpeu series of ac/dc converters is available with multiple outputs and output power from 1300 w up to 3000 w. all models incorporate active power factor correction (pfc). other standard features include current and voltage monitoring, overvoltage, overtemperature as well as short circuit protection. these power supplies were designed to power radio - frequency power amp lifier (rfpa) applications in the broadcasting industry.
bpeu 3000 ? 201 5 bel power solutions, inc. 866.513.2839 tech.support@psbel.com d - 3000 - st02 _ 001 parameter description / condition voltage: 185 C 264 vac single - phase / 170 C 242 vac three - phase frequency: 4763 hz efficiency: > 88% @ full - load @ vnom power factor: > 0. 98 @ full - load @ 230 vac single - phase / > 0. 92 @ full - load @ 208 vac three - phase output voltage (vdc) inom (a) imax (a) tolerance ( % ) r ipple ( % ) power (w) v1 +41 to +50 * 23. 5 25 2 < 2 1175 v2 +41 to +50 * 23. 5 25 2 < 2 1175 v3 +41 to +50 * 23. 5 25 2 < 2 1175 v4 +41 to +50 * 23. 5 25 2 < 2 1175 v5 +26 to 48** 2. 5 3 5 < 5 120 v6 +5. 1*** 500 ma 1 5 < 5 5. 1 * v1 - v4 adjustable by multi - turns trimmer set on board. imax total v1 - v4 = 58 a @ 50 v ** output v5 increase with temperature (jumper jp1 pos. a); output v5 48 v (jumper jp1 pos. b). *** internal or diode parameter description / condition over - load: constant current short - circuit: h iccup mode (with auto recovery) over - voltage: s et point = 60 v 5%, not automatic return to operation over - temperature: s et point = 75c heatsink, 90c internal, automatic return to operation with hysteresis 10c general: p rovide external fuses or equivalent protection parameter description / condition output v1 current monitor im l inear analogic signal 200 mv vm l inear analogic signal 100 mv inhibit no connected = on; +5 v = off (referenced to com) over temperature alarm otp +5 v = alarm, 0 v = ok leds green led v1 - v4 = on; green led v5 = on; green led v6 = on red led inhibit v1 - v4 output v1 - v4 current monitor im l inear analogic signal 200 mv parameter description / condition operating temperature: see thermal protection storage temperature: \
bpeu 3000 ? 201 5 bel power solutions, inc. 866.513.2839 tech.support@psbel.com d - 3000 - st02 _ 001 parameter description / condition safety: en60950 - 1 emc / emi en55022 con ducted noise ( industrial level ) en61000 \ 4 \ 4 fast \ transients en61000 \ 4 \ 5 surges ( 2 kv common 1 kv differential) en61000 \ 4 \ 11 voltage \ dips en61000 \ 3 \ 2 harmonics current ce mark parameter description / condition input n 4 fast \ on male connectors (6. 35 x 0. 8 mm) output 4 pole screw type terminal block 30 a (outputs v1 - v4 positive pole, negative pole is connected to the case) 4 pole screw typ e terminal block 5 a (outputs v5 - v6) signals / controls male flat type connector 10 pole dil figure 1 C connections
bpeu 3000 ? 201 5 bel power solutions, inc. 866.513.2839 tech.support@psbel.com d - 3000 - st02 _ 001 parameter description / condition materials case: aluminium cover : aluminium fixing n 4 hole ? 7 mm (see d imensions ) dimensions (w x h x d) 140 x 73 x 400 mm notes: tolerances 0. 5 mm max figure 2 - mechanical drawing nuclear and medical applications - products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. technical revisions - the appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. specifications are subject to change without notice.


▲Up To Search▲   

 
Price & Availability of BPEU3000

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X